1. When trying to enroll for the first time; it does not enroll:
cli> 'exenroll 5100'
Enrolling for: lsi-mono
Checking Expando300 Hardware configuration...
Disabling auto-rebuild on all controllers.
Marking any 'bad' drives as 'good'.
Importing foreign configurations.
Checking for valid gstripes to be removed. (please wait)
No gstripes found.
Expando300 hardware check complete.
Halting dependent subsystems... NPperf stop...
done
Can't find label 5100
Known Labels are:
2. Only half of the drives are seen in the raid status: (missing (12) drives in expansion chassis)
RAID menu: st
ARX5100-00000 (rev. 2013-08)
mfi0/0 status as of 2015/10/05-12:24:05 GMT: ONLINE
Model Serial SMART Port
Name Number Number Status Status
0:245:00 ST1000NM0033-9ZM173 Z1W3Q7M8 OK Online, Spun Up
0:245:01 ST1000NM0033-9ZM173 Z1W3VE55 OK Online, Spun Up
0:245:02 ST1000NM0033-9ZM173 Z1W3VE4Z OK Online, Spun Up
Volume Volume RAID Volume Volume
ID Name Level Size Status
VD0/0 ARX5100OS 5 1.8TB Optimal
mfi0/1 status as of 2015/10/05-12:24:05 GMT: ONLINE
Model Serial SMART Port
Name Number Number Status Status
0:245:03 ST3000NM0033-9ZM178 Z1Z7KR17 OK Online, Spun Up
0:245:04 ST3000NM0033-9ZM178 Z1Z774S1 OK Online, Spun Up
0:245:05 ST3000NM0033-9ZM178 Z1Z76VWZ OK Online, Spun Up
0:245:06 ST3000NM0033-9ZM178 Z1Z7KR7D OK Online, Spun Up
0:245:07 ST3000NM0033-9ZM178 Z1Z73F6M OK Online, Spun Up
0:245:08 ST3000NM0033-9ZM178 Z1Z7E2YH OK Online, Spun Up
0:245:09 ST3000NM0033-9ZM178 Z1Z7HV46 OK Online, Spun Up
0:245:10 ST3000NM0033-9ZM178 Z1Z7MK8F OK Online, Spun Up
0:245:11 ST3000NM0033-9ZM178 Z1Z7GCVK OK Online, Spun Up
0:245:12 ST3000NM0033-9ZM178 Z1Z7J4EM OK Online, Spun Up
0:245:13 ST3000NM0033-9ZM178 Z1Z7E5WD OK Online, Spun Up
0:245:14 ST3000NM0033-9ZM178 Z1Z7LXCE OK Online, Spun Up
0:245:15 ST3000NM0033-9ZM178 Z1Z7KCRG OK Online, Spun Up
Volume Volume RAID Volume Volume
ID Name Level Size Status
VD0/1 ARX5100HSC 6 30.0TB Optimal
mfi0/2 status as of 2015/10/05-12:24:15 GMT: ONLINE
Model Serial SMART Port
Name Number Number Status Status
0:049:00 ST3000NM0033-9ZM178 Z1Z3SWJP OK Online, Spun Up
0:049:01 ST3000NM0033-9ZM178 Z1Z3S3PK OK Online, Spun Up
0:049:02 ST3000NM0033-9ZM178 Z1Z3QQP9 OK Online, Spun Up
0:049:03 ST3000NM0033-9ZM178 Z1Z3QDJA OK Online, Spun Up
0:049:04 ST3000NM0033-9ZM178 Z1Z3T9TT OK Online, Spun Up
0:049:05 ST3000NM0033-9ZM178 Z1Z3TCKD OK Online, Spun Up
0:049:06 ST3000NM0033-9ZM178 Z1Z3QEK3 OK Online, Spun Up
0:049:07 ST3000NM0033-9ZM178 Z1Z3RW9Y OK Online, Spun Up
0:049:08 ST3000NM0033-9ZM178 Z1Z3QCNA OK Online, Spun Up
0:049:09 ST3000NM0033-9ZM178 Z1Z3RSGR OK Online, Spun Up
0:049:10 ST3000NM0033-9ZM178 Z1Z3TGDR OK Online, Spun Up
0:049:11 ST3000NM0033-9ZM178 Z1Z3SBHJ OK Online, Spun Up
Volume Volume RAID Volume Volume
ID Name Level Size Status
VD0/2 E3B-NAEE3490003 6 27.3TB Optimal