Issue
The SteelCentral NetProfiler user interface will hang for several minutes when navigating to the DEFINITIONS > Host Groups > ByFunction page
Solution
This issue occurs due to the Inside Address Configuration on the NetProfiler having over 100 CIDRs configured. The number of CIDRS must be reduced by summarizing as many subnets as possible and reducing the total number of CIDRs configured down to about 20 CIDRs.

The Inside Address Configuration can be found in the page Configuration > General Settings and then by scrolling down to the Inside Address Configuration form as seen below.

Please contact Riverbed Support  for further assistance if reducing the number of CIDRs does not resolve this issue