Vertica installation fails to complete due to limited space on the root partition

Categories:
Solution Number:
S38224
Last Modified:
2024-04-22
Description
 
 
Issue
When installing the Aternity on premise platform 12.x , the Vertica installation reports the following in the cli as well as the installation log - 
INFO: Installing Vertica package
warning: /data/setup/internal/rpms/vertica-12.0.4-20.rpm: Header V3 RSA/SHA256 Signature, key ID f54b82a0: NOKEY
Verifying... ########################################
Preparing... ########################################
installing package vertica-12.0.4-20.x86_64 needs 1xxx MB on the / filesystem
2024-04-08 15:43:57, ERROR: Error installing Vertica package. Please contact Aternity support.
Solution
When installing the Aternity on premise platform, the system sizing documentation specifies the required space for the Vertica data partition based on the deployment size
Choose Aternity Sizing and Hardware System Requirements

In addition to our documented data requirements,  the installation requires around 1.5gb on the root partition or / in order to copy the installer files and write the installation logs . In most cases the root(/) partition has more than enough space however in cases where there is under 1.5gb available, the installer may fail. To resolve the issue clear 1.5gb from the root(/) file system and re run the Vertica installation again.
Environment
Aternity on Premise
Attachments